Select a Size
Inquire
This item is not able to be purchased as a guest user. For further information, please contact us at +1 866 227 3811or
.About This Item
Skip To
material
PVDF
polyester support
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
silicone outer O-ring
silicone-coated EPDM rubber lead O-ring
Quality Level
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
gamma compatible
product line
Opticap® XL 10
feature
gamma compatible
hydrophilic
manufacturer/tradename
Opticap®
parameter
≤21.1 mL/min air diffusion at 3.9 bar (56 psig) and 23 °C (in water)
1.0 bar max. inlet pressure (15 psi) at 80 °C
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
technique(s)
sterile filtration: suitable
L
33.5 cm (13.2 in.)
W
4.2 in.
cartridge nominal length
10 in. (25 cm)
diam.
10.7 cm (4.2 in.)
filtration area
0.73 m2
inlet connection diam.
1.5 in.
inlet to outlet W
33.5 cm (13.2 in.)
outlet connection diam.
9/16 in.
impurities
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
gravimetric extractables
≤25 mg/capsule
matrix
Durapore®
pore size
0.1 μm
input
sample type liquid
bubble point
≥4830 mbar (70 psig), air with water at 23 °C
fitting
1/4 in. drain/vent hose barb (with double O-ring Seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet)
1 of 4
This Item | KVVLG10FH1 | KVVLG10TT1 | KVVLG10HH1 |
|---|---|---|---|
| pore size 0.1 μm | pore size 0.1 μm | pore size 0.1 μm | pore size 0.1 μm |
| product line Opticap® XL 10 | product line Opticap® XL 10 | product line Opticap® XL 10 | product line Opticap® XL 10 |
| filtration area 0.73 m2 | filtration area 0.73 m2 | filtration area 0.73 m2 | filtration area 0.73 m2 |
| technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable |
| manufacturer/tradename Opticap® | manufacturer/tradename Opticap® | manufacturer/tradename Opticap® | manufacturer/tradename Opticap® |
| material PVDF , polyethylene support, polypropylene housing, silicone outer O-ring, polyester support, polypropylene vent cap, polypropylene (gamma-stable), silicone-coated EPDM rubber lead O-ring | material PVDF , polyester support, polyethylene support, polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap, silicone outer O-ring, silicone-coated EPDM rubber lead O-ring | material PVDF , polyester support, polyethylene support, polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap, silicone outer O-ring, silicone-coated EPDM rubber lead O-ring | material PVDF , polyester support, polyethylene support, polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap, silicone outer O-ring, silicone-coated EPDM rubber lead O-ring |
General description
Packaging
Preparation Note
3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
Analysis Note
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Legal Information
Disclaimer
Stay compliant with GMP using the Emprove® Program
Accelerate qualification, maintain compliance, and save time with Emprove® Dossiers.
Note: you will be brought to EmproveSuite.com. Your username and password are separate from SigmaAldrich.com and may differ.
Register for free and access Emprove® Dossiers within minutes. Upgrade your subscription plan to unlock advanced and customized content in the Emprove® Suite
Not finding what you are looking for? Visit the Emprove® Program Help page.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service