Skip to Content
MilliporeSigma
  • Polyethylene glycol modified magnetic carbon nanotubes as nanosorbents for the determination of methylprednisolone in rat plasma by high performance liquid chromatography.

Polyethylene glycol modified magnetic carbon nanotubes as nanosorbents for the determination of methylprednisolone in rat plasma by high performance liquid chromatography.

Journal of chromatography. A (2014-05-20)
Panfeng Yu, Hongwei Ma, Yong Shang, Ji Wu, Shun Shen
ABSTRACT

In this paper, polyethylene glycol modified (PEGylated) magnetic carbon nanotubes were developed as solid-phase extraction nanosorbents for the determination of methylprednisolone in rat plasma. The procedure mainly involved two steps including preparation of PEGylated magnetic nanosorbents and bioanalysis. Monodisperse magnetites (Fe3O4) anchored onto multi-walled carbon nanotubes (MWCNTs) were synthesized by a facile solvothermal synthesis method. The obtained MWCNTs-Fe3O4 nanomaterials were further non-covalently functionalized by a surfactant phospholipids-polyethylene glycol (DSPE-PEG). Owing to dispersibility and high enrichment ability, water-soluble PEGylated MWCNTs-Fe3O4 nanomaterials can provide more efficient way for the extraction of methylprednisolone than only MWCNTs-Fe3O4 used. The methylprednisolone could be easily extracted via π-π stacking interactions with PEGylated MWCNTs-Fe3O4. The captured methylprednisolone/nanosorbents were isolated from the matrix by placing a magnet, and desorbed by the elution solvent composed of acetonitrile. Extraction conditions such as amount of nanosorbents added, adsorption time, desorption solvent, and desorption time were investigated and optimized. The method recoveries were obtained from 88.2% to 92.9%. Limits of quantification and limits of detection of 0.01 and 0.005μg/mL were acquired, respectively. The precision ranged from 4.2% to 7.8% for within-day measurement, and for between-day variation was in the range of 5.5-9.0%. Moreover, the analytical performance obtained by PEGylated magnetic MWCNTs was compared with that of magnetic MWCNTs. The results indicated that the approach based on PEGylated magnetic MWCNTs was useful for the analysis of methylprednisolone in the complex plasma.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, anhydrous, 99.8%
Supelco
Ethylene glycol, analytical standard
Supelco
Methanol, analytical standard
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, SAJ special grade
Sigma-Aldrich
Methanol, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Supelco
Ethylene glycol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
Ammonia, anhydrous, ≥99.98%
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Supelco
Ethylene glycol solution, suitable for NMR (reference standard), 80% in DMSO-d6 (99.9 atom % D), NMR tube size 5 mm × 8 in.
Sigma-Aldrich
Ammonia solution, 0.4 M in THF
Sigma-Aldrich
Ethylene glycol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Ethylene glycol, SAJ first grade, ≥99.0%
Sigma-Aldrich
Methanol, JIS 300, ≥99.8%, suitable for residue analysis
Sigma-Aldrich
Methanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Ethylene glycol, JIS special grade, ≥99.5%
Sigma-Aldrich
Ammonia-14N, 99.99 atom % 14N
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
USP
Ethylene glycol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, 99.93%
Sigma-Aldrich
Ethylene glycol, BioUltra, ≥99.5% (GC)
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%