Skip to Content
MilliporeSigma
  • Determination of high-intensity sweeteners in river water and wastewater by solid-phase extraction and liquid chromatography-tandem mass spectrometry.

Determination of high-intensity sweeteners in river water and wastewater by solid-phase extraction and liquid chromatography-tandem mass spectrometry.

Journal of chromatography. A (2015-04-05)
Paula Arbeláez, Francesc Borrull, Eva Pocurull, Rosa Maria Marcé
ABSTRACT

High-intensity sweeteners have been suggested as potential organic contaminants due to their widespread use in food, drugs and sanitary products. As a consequence, they are introduced into the environment by different pathways, affecting aquatic life. In this study, a method based on solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) has been developed and validated for the determination of eight sweeteners (saccharin, cyclamate, aspartame, acesulfame, neohesperidin dihydrochalcone, sucralose, stevioside and glycyrrhizic acid) in river water and wastewater. To get the maximum recoveries in SPE, several commercial sorbents were tested and Oasis HLB gave the best results, with recoveries higher than 41% for all of the compounds in the different matrices. Method limits of detection were in the range of 0.001-0.04μg/L in river water and 0.01-0.5μg/L in influent and effluent wastewater. Method reproducibility between days (n=5) was below 15% for all compounds. The method was applied to the determination of sweeteners in various river waters and wastewaters in Catalonia. Cyclamate, aspartame, neohesperidin dihydrochalcone, acesulfame and sucralose were found in river water, with the two last compounds being present at the highest values (1.62μg/L for acesulfame and 3.57μg/L for sucralose). In influent and effluent wastewater, all of the compounds were found at concentration levels ranging from 0.05 to 155μg/L except for stevioside and neohesperidin dihydrochalcone, which were not detected.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ethyl acetate
Sigma-Aldrich
Ethyl acetate
Sigma-Aldrich
Ultrapure Acetonitrile
Sigma-Aldrich
Hexane, JIS special grade, ≥96.0%
Sigma-Aldrich
Acetonitrile, suitable for chromatography
Sigma-Aldrich
Ethyl acetate, suitable for HPLC
Sigma-Aldrich
Hexane, suitable for HPLC
Sigma-Aldrich
2-Propanol, suitable for HPLC
Sigma-Aldrich
2-Propanol, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
Formic acid, JIS special grade, ≥98.0%
Sigma-Aldrich
Hexane, JIS 300, ≥96.0%, suitable for residue analysis
Sigma-Aldrich
Hexane, ≥96.0%, suitable for residual phthalate analysis
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Dichloromethane, JIS special grade, ≥99.0%
Sigma-Aldrich
2-Propanol, SAJ first grade, ≥99.0%
Sigma-Aldrich
Dichloromethane, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Ethyl acetate, JIS 300, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Hexane, JIS 1000, ≥96.0%, suitable for residue analysis
Sigma-Aldrich
Ethyl acetate, JIS special grade, ≥99.5%
Sigma-Aldrich
L-Lysine monohydrochloride, SAJ special grade, ≥99.0%
Sigma-Aldrich
Hexane, SAJ first grade, ≥95.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 300
Sigma-Aldrich
Ethyl acetate, SAJ first grade, ≥99.0%
Sigma-Aldrich
Ethyl acetate, JIS 1000, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 1000
Sigma-Aldrich
Hexane, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Ethyl acetate, ≥99%, FCC, FG