MilliporeSigma
All Photos(1)

1.14547

Supelco

Nitrite Cell Test

photometric, 0.03-2.30 mg/L (NO2-), 0.010-0.700 mg/L (NO2-N), Spectroquant®

product line

Spectroquant®

Quality Level

specific analyte(s)

nitrite

reaction suitability

reaction type: Griess reaction

measuring range

0.010-0.700 mg/L (NO2-N)
0.03-2.30 mg/L (NO2-)

technique(s)

photometry: suitable

compatibility

for use with Spectroquant® Move 100
for use with Spectroquant® Nova 60 A
for use with Spectroquant® Prove 100
for use with Spectroquant® Prove 300
for use with Spectroquant® Prove 600

detection method

photometric

storage temp.

15-25°C

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
1.147761.100571.16973
Nitrite Cell Test photometric, 0.03-2.30 mg/L (NO2-), 0.010-0.700 mg/L (NO2-N), Spectroquant®

Supelco

1.14547

Nitrite Cell Test

Nitrite Test photometric, 0.002-1.00 mg/L (NO2-N), 0.007-3.28 mg/L (NO2-), Spectroquant®

Supelco

1.14776

Nitrite Test

Nitrite Test colorimetric, 0.5-10 mg/L (NO2-), MQuant®

Supelco

1.10057

Nitrite Test

Nitrite Test reflectometric, 0.5-25.0 mg/L (NO2-), for use with REFLECTOQUANT®

Supelco

1.16973

Nitrite Test

measuring range

0.010-0.700 mg/L (NO2-N), 0.03-2.30 mg/L (NO2-)

measuring range

0.002-1.00 mg/L (NO2-N), 0.007-3.28 mg/L (NO2-)

measuring range

0.5-10 mg/L (NO2-)

measuring range

0.5-25.0 mg/L (NO2-)

technique(s)

photometry: suitable

technique(s)

photometry: suitable

technique(s)

-

technique(s)

-

compatibility

for use with Spectroquant® Move 100, for use with Spectroquant® Nova 60 A, for use with Spectroquant® Prove 100, for use with Spectroquant® Prove 300, for use with Spectroquant® Prove 600

compatibility

for use with Spectroquant® Move 100, for use with Spectroquant® Nova 60 A, for use with Spectroquant® Prove 100, for use with Spectroquant® Prove 300, for use with Spectroquant® Prove 600

compatibility

-

compatibility

RQflex® 10 Plus, RQflex® 20, for use with REFLECTOQUANT®

detection method

photometric

detection method

photometric

detection method

colorimetric

detection method

reflectometric

product line

Spectroquant®

product line

Spectroquant®

product line

MQuant®

product line

-

General description

Method: photometric 0.03 - 2.30 mg/l NO₂⁻ 0.010-0.700 mg/l NO₂-N Spectroquant®
The method is analogous to EPA 354.1, APHA 4500-NO2 - B, and DIN EN 26777.
This Spectroquant® Nitrite Cell Test allows the accurate quantification of the nitrite content in aqueous samples.
Method applied: In acidic solution nitrite ions react with sulfanilic acid to form a diazonium salt. This reacts with N-(1-naphthyl)ethylenediamine dihydrochloride to form a red-violet azo dye that is determined photometrically.
The Spectroquant® Cell Tests come with prefilled 16 mm round cells and all the required reagents to perform the analysis according to the instruction leaflet provided .
All Spectroquant® Cell and Reagent Test Kits are equipped with the unique Live ID (2DD barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.

Legal Information

SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictograms

Exclamation mark

Signal Word

Warning

Hazard Statements

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1

Storage Class Code

11 - Combustible Solids

WGK

WGK 2


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Protocols

Analytical Method: Nitrite in potato instant powder

Photometric determination using the Griess method subsequent to extraction

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service