The efficiency available for the separation (and by this resolution) is always dependent on column length. Reducing the column length to half is reducing the efficiency of the column to half. The principle is the same with RP and HILIC - there is no difference.
Select a Size
$1,050.00
$1,050.00
About This Item
Skip To
Product Name
SeQuant® ZIC-HILIC™ 3.5µm,100Å 50 x 2.1 mm, PEEK-lined stainless steel column, suitable for HPLC
material
PEEK-lined stainless steel column
Quality Level
agency
suitable for USP L114
product line
SeQuant®
feature
endcapped: no
parameter
550 bar pressure
70 °C max. temp.
technique(s)
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)
column L × I.D.
5 cm × 2.1 mm
matrix
fully porous particle
matrix active group
ZIC-HILIC bonding phase
particle size
3.5 μm
pore size
100 Å pore size
operating pH
2-7.5
separation technique
hydrophilic interaction (HILIC)
storage temp.
no temp limit
1 of 4
This Item | 1.50445 | 1.50446 | 1.50447 |
|---|---|---|---|
| matrix active group ZIC-HILIC bonding phase | matrix active group ZIC-HILIC bonding phase | matrix active group ZIC-HILIC bonding phase | matrix active group ZIC-HILIC bonding phase |
| particle size 3.5 μm | particle size 3.5 μm | particle size 3.5 μm | particle size 3.5 μm |
| separation technique hydrophilic interaction (HILIC) | separation technique hydrophilic interaction (HILIC) | separation technique hydrophilic interaction (HILIC) | separation technique hydrophilic interaction (HILIC) |
| matrix fully porous particle | matrix fully porous particle | matrix fully porous particle | matrix fully porous particle |
| pore size 100 Å pore size | pore size 200 Å pore size | pore size 200 Å pore size | pore size 200 Å pore size |
| product line SeQuant® | product line SeQuant® | product line SeQuant® | product line SeQuant® |
General description
Analysis Note
Symmetry (Cytosine): 0.95 - 1.40
Legal Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
-
Do they have concerns about potential performance issues when opting for a smaller dimension column,considering that this is a HILIC column? Especially for the analysis of sulfites using the 150 x 2.1, 5µm (100 A) column for the conversion of free sulfites to HMS (hydroxymethylsulfonate) and subsequent analysis by LC-MS/MS. Is there a risk of reduced performance when using a column size of 50 x 2.1 mm, 3.5 µ (100 A) instead of the larger format for SeQuant ZIC-HILIC columns?
1 answer-
Helpful?
-
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service