Product Name
Aervent® 50 Capsule Filter, pore size 0.2 μm
Quality Level
material
PTFE membrane
polypropylene
polypropylene housing
sterility
non-sterile
sterilization compatibility
gamma compatible
product line
Aervent®
feature
hydrophobic
manufacturer/tradename
Aervent®
parameter
2.1 bar max. differential pressure at 25 °C
4.1 bar max. inlet pressure (60 psi) at 25 °C
technique(s)
gas filtration: suitable
L
7.2 cm (2.84 in.)
W
2.4 in.
diam.
6.2 cm (2.4 in.)
filtration area
19.6 cm2
impurities
≤0.5 EU/mL (LAL test, Aqueous extraction)
gravimetric extractables
≤1.0 mg
matrix
Aervent®
pore size
0.2 μm pore size
bubble point
≥1100 mbar (16 psig), nitrogen with 60/40% IPA/water at 23 °C
fitting
inlet/outlet hose for 6.5-9.5 mm I.D. silicone tubing
shipped in
ambient
1 of 4
This Item | MTGR65000 | MTGR75000 | MTGR75010 |
|---|---|---|---|
| pore size 0.2 μm pore size | pore size 0.2 μm pore size | pore size 0.2 μm pore size | pore size 0.2 μm pore size |
| product line Aervent® | product line Aervent® | product line Aervent® | product line Aervent® |
| technique(s) gas filtration: suitable | technique(s) gas filtration: suitable | technique(s) gas filtration: suitable | technique(s) gas filtration: suitable |
| filtration area 19.6 cm2 | filtration area 19.6 cm2 | filtration area 19.6 cm2 | filtration area 19.6 cm2 |
| matrix Aervent® | matrix Aervent® | matrix Aervent® | matrix Aervent® |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
Analysis Note
Quantitative retention of 107 CFU/cm2Brevundimonas diminuta (ATCC® 19146) per ASTM F838-83 methodology
Application
- Sterile venting of vessels and carboys
- Autoclave vacuum break lines
- Low volume sterile filtration of non-aqueous fluids
- Small fermenter inlet and exhaust gas filtration
General description
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Preparation Note
10 autoclave cycles of 30 min @ 130 °C; not in-line steam sterilizable
Legal Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service