Skip to Content
MilliporeSigma
  • Simultaneous determination of propofol and its glucuronide in whole blood by liquid chromatography-electrospray tandem mass spectrometry and the influence of sample storage conditions on the reliability of the test results.

Simultaneous determination of propofol and its glucuronide in whole blood by liquid chromatography-electrospray tandem mass spectrometry and the influence of sample storage conditions on the reliability of the test results.

Journal of pharmaceutical and biomedical analysis (2015-03-17)
Lambert K Sørensen, Jørgen B Hasselstrøm
ABSTRACT

Propofol (2,6-diisopropylphenol) is commonly used as an anaesthetic agent but is also abused for recreational purposes. Several cases of fatalities involving self-administered propofol have been reported. For rapid quantification of propofol and propofol β-d-glucuronide (propofol G) in clinical and forensic cases, an ultra-performance liquid chromatography-tandem mass spectrometry method using pneumatically assisted electrospray ionisation has been developed. The technique has been validated on both ante-mortem and post-mortem human whole blood. The proteins in the blood samples were removed by the addition of a mixture of methanol and acetonitrile, and the extract was cleaned up by solid phase extraction. The extract was concentrated in dimethyl sulphoxide. The system was calibrated using matrix-matched calibrants combined with isotope dilution. The lower limits of quantification were 0.01 and 0.02mg/L for propofol and 0.02 and 0.04mg/L for propofol G in ante-mortem and post-mortem whole blood, respectively. The relative intra-laboratory reproducibility standard deviation was less than 10% at concentrations of 0.2mg/L or higher. The mean true extraction recovery was 85% for propofol and 81% for propofol G. The trueness of the propofol determination expressed as the relative bias of the test results was within ±6% at concentration levels of 0.01-8.5mg/L. Propofol was less stable in blood stabilised with a citrate-EDTA-fluoride mixture than in blood stabilised with an oxalate-fluoride mixture. The stability was lower at -20°C than at 5°C and -80°C. Propofol G did not show instability under the storage conditions tested.

MATERIALS
Product Number
Brand
Product Description

Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetic acid solution, suitable for HPLC
Sigma-Aldrich
Methanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acetic acid, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Acetic acid, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Acetic acid, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Acetic acid, glacial, puriss., 99-100%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Acetic acid, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Acetic acid, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.8-100.5%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Acetic acid, ≥99.7%
Sigma-Aldrich
Acetic acid, JIS special grade, ≥99.7%
Sigma-Aldrich
Acetic acid, 99.5-100.0%
Sigma-Aldrich
Methanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Acetic acid, SAJ first grade, ≥99.0%
Sigma-Aldrich
Methanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Acetic acid, ≥99.7%
Sigma-Aldrich
Acetic acid, ≥99.7%, suitable for amino acid analysis