Produktname
Millipore Express® SHRP, Opticap® XL Kapsel, inlet connection diam. 9/16 in., Opticap® XL 3, pore size 0.5/0.1 μm, cartridge nominal length 3 in. (7.5 cm)
Materialien
polyethersulfone
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
polysulfone
silicone seal
Qualitätsniveau
Einhaltung gesetzlicher Vorschriften
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Sterilität
non-sterile
Kompatibilität mit Sterilisationsverfahren
autoclavable compatible
Produktlinie
Opticap® XL 3
Leistungsmerkmale
hydrophilic
Hersteller/Markenname
Millipore Express®
Parameter
≤7.2 mL/min air diffusion at 3.45 bar (50 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
Methode(n)
sterile filtration: suitable
Länge
17.3 cm (6.8 in.)
Breite
4.2 in.
Nennlänge Kartusche
3 in. (7.5 cm)
Durchmesser
10.7 cm (4.2 in.)
Filtrationsfläche
0.13 m2
Durchm. Einlassanschluss
9/16 in.
Breite Einlass bis Auslass
17.3 cm (6.8 in.)
Durchm. Auslassanschluss
9/16 in.
Verunreinigungen
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matrix
Millipore Express® SHR (w/Prefilter)
pore size
0.5/0.1 μm pore size
Blasenpunkt
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C
Fitting
1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet hose barb
outlet hose barb
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
1 of 4
Dieser Artikel | KHVEA03TH3 | KHVES03HH3 | KHVEG03HH3 |
|---|---|---|---|
| pore size 0.5/0.1 μm pore size | pore size 0.5/0.1 μm pore size | pore size 0.5/0.1 μm pore size | pore size 0.5/0.1 μm pore size |
| product line Opticap® XL 3 | product line Opticap® XL 3 | product line Opticap® XL 3 | product line Opticap® XL 300 |
| technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable |
| filtration area 0.13 m2 | filtration area 0.13 m2 | filtration area 0.13 m2 | filtration area 0.13 m2 |
| material polyethersulfone , polypropylene housing, polypropylene vent cap, silicone seal, polysulfone , polypropylene support | material polyethersulfone , polypropylene , polypropylene housing, polypropylene support, polypropylene vent cap, polysulfone , silicone seal | material polyester support, polyethersulfone , polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap (Gamma stable), polysulfone , silicone seal | material polyester support, polyethersulfone , polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap (Gamma stable), polysulfone , silicone seal |
| sterility non-sterile | sterility non-sterile | sterility irradiated, sterile | sterility non-sterile |
Allgemeine Beschreibung
Verpackung
Angaben zur Herstellung
3 Autoklavenzyklen von 60 min bei 126 °C; nicht inline dampfsterilisierbar
Hinweis zur Analyse
Quantitative Rückhaltung von Brevundimonas diminuta bei einer Mindestbeaufschlagung von 1 x 10⁷ KBE/cm² unter Anwendung der ASTM®-F838-Methode.
Nach Sterilisation und einem kontrollierten Durchspülen mit einer Wassermenge von 5,5 l wiesen die Proben bei 25 °C weniger als 500 ppb TOC gemäß USP <64> und weniger als 1,3 µS/cm gemäß USP <64> auf.
Sonstige Hinweise
- Rückhaltung von Organismen: Mikroorganismen
- Wirkungsweise: Filtration (Größenausschluss)
- Anwendung: Bio-Processing
- Verwendungszweck: Reduziert oder entfernt Mikroorganismen/Keimbelastung
- Gebrauchsanweisung: Bitte beachten Sie den Abschnitt Installation des Benutzerhandbuchs für OPTICAP® XL Kapseln und OPTICAP® XLT Kapseln
- Lagerung: An einem trockenen Ort aufbewahren
- Entsorgung: Entsorgung gemäß den geltenden lokalen, regionalen und nationalen Vorschriften
Rechtliche Hinweise
Haftungsausschluss
Bleiben Sie mit dem Emprove®-Programm GMP-konform
Beschleunigen Sie die Qualifizierung, halten Sie die Vorschriften ein und sparen Sie Zeit mit Emprove® Dossiers.
Hinweis: Sie werden zu EmproveSuite.com weitergeleitet. Ihr Benutzername und Passwort sind von SigmaAldrich.com getrennt und können abweichen.
Registrieren Sie sich kostenlos und erhalten Sie innerhalb weniger Minuten Zugang zu Emprove® Dossiers. Aktualisieren Sie Ihr Abonnement, um erweiterte und angepasste Inhalte in der Emprove® Suite freizuschalten.
Sie finden nicht, was Sie suchen? Besuchen Sie die Emprove® Programm-Hilfeseite.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Active Filters
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung