Scegli un formato
Chiedi
Non è possibile acquistare questo articolo come utente ospite. Per ulteriori informazioni ti preghiamo di contattarci +39 02 38 59 40 13o
.Informazioni su questo articolo
Vai a
Nome del prodotto
Millipore Express® SHF, Opticap® XLT Capsule, Opticap® XLT 20, cartridge nominal length 20 in. (50 cm), filter diam. 10.7 cm (4.2 in.)
Materiali
polyester support
polypropylene device (gamma stable)
polypropylene housing
polypropylene vent cap
polysulfone device
silicone seal
Livello qualitativo
Conformità normativa
meets FDA 21 CFR 177-182 (all component materials)
Sterilità
non-sterile
Compatibilità con la sterilizzazione
gamma compatible
Nome Commerciale
Opticap® XLT 20
Caratteristiche
hydrophilic
Produttore/marchio commerciale
Millipore Express®
Parametri
≤62.5 mL/min air diffusion at 2.8 bar (40 psig) (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
tecniche
sterile filtration: suitable
Larghezza
7.8 in.
Lunghezza nominale della cartuccia
20 in. (50 cm)
Lungh. del dispositivo
62.5 cm (24.6 in.)
Dimensioni del dispositivo
20 in.
Diam. filtro
10.7 cm (4.2 in.)
Superficie filtrante del filtro
1.14 m2
Impurezze
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)
Matrice
Millipore Express® SHF
Dimensione pori
0.2 μm pore size
Punto di bolla
≥4000 mbar (58 psig), air with water
Raccordi
(38 mm (1 ½ in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
1 of 4
Questo articolo | KGEPG1TTB1 | KGEPG3TTB1 | KGEPG3TTH1 |
|---|---|---|---|
| pore size 0.2 μm pore size | pore size 0.2 μm pore size | pore size 0.2 μm pore size | pore size 0.2 μm pore size |
| technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable |
| product line Opticap® XLT 20 | product line Opticap® XLT 10 | product line Opticap® XLT 30 | product line Opticap® XLT 30 |
| manufacturer/tradename Millipore Express® | manufacturer/tradename Millipore Express® | manufacturer/tradename Millipore Express® | manufacturer/tradename Millipore Express® |
| material polyester support, polypropylene housing, polysulfone device, polypropylene device (gamma stable), silicone seal, polypropylene vent cap | material polyester support, polypropylene device (gamma stable), polypropylene housing, polypropylene vent cap, polysulfone device, silicone seal | material polyester support, polypropylene device (gamma stable), polypropylene housing, polypropylene vent cap, polysulfone device, silicone seal | material polyester support, polypropylene device (gamma stable), polypropylene housing, polypropylene vent cap, polysulfone device, silicone seal |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
Descrizione generale
Confezionamento
Nota sulla preparazione
Gamma Compatible to 45 kGy. May be autoclaved for 3 cycles of 60 min at 123 °C; not in-line steam sterilizable
Risultati analitici
Altre note
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Note legali
Mantenere la conformità alle GMP utilizzando il programma Emprove®.
Accelerate la qualificazione, mantenete la conformità e risparmiate tempo con Emprove® Dossiers.
Nota: verrete portati su EmproveSuite.com. Il vostro nome utente e la vostra password sono separati da SigmaAldrich.com e possono essere diversi.
Registrati gratuitamente e accedi a Emprove® Dossiers in pochi minuti. Aggiornate il vostro piano di abbonamento per sbloccare contenuti avanzati e personalizzati nella Emprove® Suite.
Non trovate quello che state cercando? Visitate la pagina di aiuto del programma Emprove®..
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Contenuto correlato
Millipore Express Family Guide
Filtri attivi
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica