Passa al contenuto
Merck

SVEPA25NB6

Millipore Express® SHR 0.1µm, OptiScale® 25mm Capsule

Fittings NB, Autoclavable

Sinonimo/i:

Millipore Express SHR Optiscale 25mm 0.1 μm NB

Autenticati per visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

6 PKG

162,00 €

162,00 €


Spedizione prevista il05 dicembre 2025Dettagli



Informazioni su questo articolo

Codice UNSPSC:
23151806
eCl@ss:
32031690
NACRES:
NB.24

Vai a

Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti

Nome del prodotto

Millipore Express® SHR, OptiScale® Capsule, OptiScale® 25, filtration area 3.5 cm2

Materiali

polyethersulfone membrane
polypropylene
polypropylene support
polypropylene vent cap

Livello qualitativo

Conformità normativa

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Sterilità

non-sterile

Compatibilità con la sterilizzazione

autoclavable compatible

Nome Commerciale

OptiScale® 25

Caratteristiche

hydrophilic

Produttore/marchio commerciale

Millipore Express®

Parametri

4.1 bar max. inlet pressure (60 psi) at 25 °C
60 psi max. differential pressure (4.1 bar) at 25 °C (forward)

tecniche

sterile filtration: suitable

Lunghezza

3.9 cm (1.52 in.)

Lunghezza nominale della cartuccia

1.52 in. (39 mm)

Diametro

3.1 cm (1.2 in.)

Superficie filtrante

3.5 cm2

Impurezze

≤0.25 EU/mL (LAL test, Aqueous extraction)
<0.25  EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Matrice

Millipore Express® SHR

Dimensione pori

0.1 μm

Raccordi

female Luer-Lok® inlet connection
male Luer-Lok® outlet connection
(Female Luer-Lok® Inlet/Male Luer Slip Outlet)

Condizioni di spedizione

ambient

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 4

Questo articolo
SHVEA25NB6SHVEA47FF3SHVEA47HH3
pore size

0.1 μm

pore size

-

pore size

-

pore size

-

filtration area

3.5 cm2

filtration area

3.5 cm2

filtration area

17.7 cm2

filtration area

17.7 cm2

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

product line

OptiScale® 25

product line

OptiScale® 25

product line

OptiScale® 47

product line

OptiScale® 47

matrix

Millipore Express® SHR

matrix

Millipore Express® SHR (w/Prefilter)

matrix

Millipore Express® SHR (w/Prefilter)

matrix

Millipore Express® SHR (w/Prefilter)

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

Descrizione generale

Device Configuration: Capsule

Nota sulla preparazione

Sterilization Method
1 autoclave cycle of 60 min @ 123 °C
This product was manufactured with a Millipore Express membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Risultati analitici

TOC/Conductivity
After sterilization and a controlled water flush of 15 mL, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64>.
This product was tested and passes the USP <78> test for particulates in injectables.

Altre note

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation and wetting sections of OPTISCALE®-25 user guide
  • Storage Statement: Please refer to OPTISCALE®-25 user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Note legali

Luer-Lok is a registered trademark of Becton-Dickinson & Co.
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OptiScale is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Articoli

Aseptic filters are offered in disposable capsules and cartridge formats. This guide will help you find the right format for your bioburden control.

Contenuto correlato

Learn more mAb upstream processing, specifically on the products designed for efficient sterile filtration of cell culture media and media components.

Selecting the right membrane filter for cell culture media filtration is critical for increased cell viability and viable cell density.

Learn how prefilters and bioburden control can improve the efficiency of downstream purification by removing particulates and protecting unit operations.

Per saperne di più sulla lavorazione a monte dei mAb, in particolare sui prodotti progettati per un'efficiente filtrazione sterile dei mezzi di coltura cellulare e dei componenti dei mezzi stessi.

Vedi tutto

Domande

Recensioni

Nessuna valutazione

Filtri attivi

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica