Millipore Express® SHR 0.1µm, Opticap® XL 3 Capsule

Fittings 1-1/2 in. TC- 9/16 in. HB, Sterile

ログイン 組織・契約価格を表示する

サイズを選択してください

現在、価格および在庫状況を閲覧できません。

この商品について

UNSPSCコード:
23151806

スキップする

テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします

製品名

ミリポアエクスプレス(Millipore Express)®SHR、オプティキャップ(Opticap)®XLカプセル, Opticap® XL 3, sterile, cartridge nominal length 3 in. (7.5 cm), filter diam. 10.7 cm (4.2 in.)

物質

polyester support
polypropylene device
polypropylene housing
polypropylene vent cap
silicone seal

品質水準

法規制遵守

meets FDA 21 CFR 177-182 (all component materials)

無菌性

irradiated
sterile

製品種目

Opticap® XL 3

特徴

hydrophilic

メーカー/製品名

Millipore Express®

パラメーター

1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

テクニック

sterile filtration: suitable

カートリッジの長さ(公称)

3 in. (7.5 cm)

デバイス L

17.3 cm (6.8 in.)

デバイスサイズ

3 in.

フィルタ直径

10.7 cm (4.2 in.)

Filter filtration area

0.17 m2

不純物

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)

Matrix

Millipore Express® SHR

ポアサイズ

0.1 μm pore size

泡立ち点

≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water

フィッティング

(38 mm (1½ in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet)

類似した製品をお探しですか? 訪問 製品比較ガイド

類似品目との比較

比較内容をすべて表示

相違点を表示

1 of 4

当該品目
KVEPS05TH1KVEPS10TH1KVEPS03TB3
pore size

0.1 μm pore size

pore size

0.1 μm pore size

pore size

0.1 μm pore size

pore size

0.1 μm pore size

product line

Opticap® XL 3

product line

Opticap® XL 5

product line

Opticap® XL 10

product line

Opticap® XL 3

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

matrix

Millipore Express® SHR

matrix

Millipore Express® SHR

matrix

Millipore Express® SHR

matrix

Millipore Express® SHR

sterility

irradiated, sterile

sterility

irradiated, sterile

sterility

irradiated, sterile

sterility

irradiated, sterile

material

polyester support, polypropylene housing, silicone seal, polypropylene device, polypropylene vent cap

material

polyester support, polypropylene device, polypropylene housing, polypropylene vent cap, silicone seal

material

polyester support, polypropylene device, polypropylene housing, polypropylene vent cap, silicone seal

material

polyester support, polypropylene device, polypropylene housing, polypropylene vent cap, silicone seal

詳細

Device Configuration: Capsule

包装

Double Easy-Open bag

調製ノート

Sterilization Method:
3 autoclave cycles of 60 min at 123 °C; not in-line steam sterilizable
This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

アナリシスノート

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.
TOC/Conductivity: After sterilization and a controlled water flush of 3.5 L, samples exhibited &#x3C 500 ppb TOC per USP &#x3C 643 &#x3C and &#x3C 1.3 μS/cm per USP &#x3C 645 &#x3C at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 1 L

その他情報

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

法的情報

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Emprove®プログラムを使用してGMPを遵守します。

Emprove® Dossiersで資格認定を加速し、コンプライアンスを維持し、時間を節約しましょう。

Dossiers をダウンロード

注意: EmproveSuite.comに移動します。ユーザー名とパスワードはSigmaAldrich.comとは別のもので、異なる場合があります

無料会員登録すると、数分でEmprove® Dossiersにアクセスできます。 購読プランをアップグレードして、Emprove® Suiteの高度でカスタマイズされたコンテンツをアンロックしてください。

お探しのものが見つかりませんか?Emprove® プログラムのヘルプページをご覧ください。.

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

質問

レビュー

評価値なし

アクティブなフィルタ

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)