Microcon and Amicon Ultra products are very similar. Both concentrate liquids down to a retentate and a filtrate. Substances bigger than the molecular weight cutoff stay on top of the membrane and are reduced from a larger initial volume to a smaller final volume. Two key differences are: the Microcon can be slightly better to use for substances in lower initial concentrations and when substances are sticky. Higher recovery can occur with Microcon due to the product being physically smaller and thus, less product is lost to the hold up volume of the membrane and plastic sides of the tube.
サイズを選択してください
この商品について
スキップする
物質
Ultracel® regenerated cellulose membrane (low binding)
polyacetal base (membrane support)
polycarbonate device top
polypropylene tube (for filtrate/concentrate)
silicone O-ring (medical-grade)
品質水準
無菌性
non-sterile
特徴
holdup volume> 10 μL
包装
pkg of 100 ea
メーカー/製品名
Microcon®
パラメーター
0.5 mL sample volume
テクニック
DNA purification: suitable
RNA purification: suitable
protein extraction: suitable
protein purification: suitable
L
4.50 cm (1.8 in.)
直径
12.3 mm
ろ過面積
0.32 cm2
有効容積
0.5 mL
ポアサイズ
10 kDa NMWCO
輸送温度
ambient
1 of 4
当該品目 | MRCF0R030 | MRCF0R100 | MRCF0R100ET |
|---|---|---|---|
| pore size 10 kDa NMWCO | pore size 30 kDa NMWCO | pore size - | pore size - |
| manufacturer/tradename Microcon® | manufacturer/tradename Microcon® | manufacturer/tradename Microcon® | manufacturer/tradename Microcon® |
| material Ultracel® regenerated cellulose membrane (low binding), polycarbonate device top, silicone O-ring (medical-grade), polyacetal base (membrane support), polypropylene tube (for filtrate/concentrate) | material Ultracel® regenerated cellulose membrane (low binding), polyacetal base (membrane support), polycarbonate device top, polypropylene tube (for filtrate/concentrate), silicone O-ring (medical-grade) | material Ultracel® regenerated cellulose membrane (low binding), polyacetal base (membrane support), polycarbonate device top, polypropylene tube (for filtrate/concentrate), silicone O-ring (medical-grade) | material Ultracel® regenerated cellulose membrane (low binding), polyacetal base (membrane support), polycarbonate device top, polypropylene tube (for filtrate/concentrate), silicone O-ring (medical-grade, dual cycle ethylene oxide (EtO) treated) |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
| parameter 0.5 mL sample volume | parameter 0.5 mL sample volume | parameter 0.5 mL sample volume | parameter 0.5 mL sample volume |
| feature holdup volume> 10 μL | feature holdup volume> 10 μL | feature holdup volume> 10 μL | feature holdup volume> 10 μL |
詳細
•希釈溶液であっても回収率は通常95%超
•最少量の検体であっても逆遠心して回収率を最大化
•ろ過したまたは濃縮したサンプルは標準的なマイクロ遠心チューブに保存できて便利
•濃縮係数は最大100X
特長:
•逆遠心により少量でも高い回収率(濃縮率20X未満)
•低結合Ultracelメンブレン
•速やかな処理
アプリケーション
特徴および利点
物理的形状
その他情報
法的情報
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
関連コンテンツ
Microcon® Centrifugal Filters simply and efficiently concentrate and desalt solutions of DNA, RNA, protein or other macromolecules, using any centrifuge that can accept 1.5 mL tubes.
The new dual cycle EtO-treated Microcon® DNA Fast Flow PCR Grade devices enable centrifugal concentration at a similar rate as the Microcon® DNA Fast Flow devices, but the EtO treatment greatly reduces the risk that no uncontrolled contaminating nucleic acids enter the analysis process. Both Microcon® devices exhibit faster flow rate (volume filtered per minute) compared to competitor centrifugal products.
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)