  • Occupational exposure to styrene in the fibreglass reinforced plastic industry: comparison between two different manufacturing processes.

Occupational exposure to styrene in the fibreglass reinforced plastic industry: comparison between two different manufacturing processes.

La Medicina del lavoro (2012-10-20)
Giovanna Tranfo, Monica Gherardi, E Paci, Mariapia Gatto, A Gordiani, Lidia Caporossi, Silvia Capanna, Renata Sisto, B Papaleo, Carla Fiumalbi, Patrizia Garofani
ABSTRACT

Styrene is used in manufacturing fiberglass reinforced plastics: and occupational exposure was related to neurotoxicology and genotoxicity. The sum of the metabolites mandelic and phenylglyoxylic acids is the ACGIH biomarker for occupational exposure with a BEI of 400 mg/g of creatinine in end shift urine corresponding to a airborne styrene concentration of 85 mg/m3. There are two main molding processes, open and closed, the last more effective at controlling worker's styrene exposure. To compare the open molding process to the compression of fiber reinforced resin foils, a kind of closed molding, monitoring the styrene exposure of workers in two production sites (A and B). Environmental Monitoring was carried out by Radiello samplers and Biological Monitoring by means of the determination of MA and PGA with HPLC/MS/MS in 10 workers at Site A and 14 at Site B. The median values for styrene exposure resulted 31.1 mg/m3 for Site A and 24.4 mg/m for Site B, while the medians for the sum of the two metabolites in the end shift urine were 86.7 e 33.8 mg/g creatinine respectively. There is a significant linear correlation between personal styrene exposure and the excretion of styrene metabolites (R = 0.74). As expected the exposure markers of the workers of the two production sites resulted higher in the open process. The analytical results of both environmental and biological monitoring were all below the occupational exposure limits, confirming the efficacy of the protective devices.

MATERIALS
Product Number
Brand
Product Description

radiello Cartridge Adsorbents, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Pricing and availability is not currently available.
radiello Triangular Support Plate, pk of 20
Pricing and availability is not currently available.
radiello Cartridge Adsorbents, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
Pricing and availability is not currently available.
radiello Barcode Labels, pk of 198
Pricing and availability is not currently available.
radiello Cartridge Adsorbents, for sampling Anaesthetic Gases/Vapors, matrix SS net with mix of mol sieve and activated charcoal (30-50 mesh), pk of 20
Pricing and availability is not currently available.
radiello Cartridge Adsorbents, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
Pricing and availability is not currently available.
radiello Vertical Adapter, threaded for standard use, pk of 20
Pricing and availability is not currently available.
radiello Cartridge Adsorbents, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
Pricing and availability is not currently available.
radiello Outdoor Shelter, pk of 10
Pricing and availability is not currently available.
radiello Anesthetic Gases and Vapor Sampler
Pricing and availability is not currently available.
radiello Replacement Mounting Strips, for use with Radiello Outdoor Shelter, pk of 100
Pricing and availability is not currently available.
Supelco
DL-Mandelic acid, analytical standard
Pricing and availability is not currently available.
radiello Clips, suspending Radiello triangular support plate, pk of 20
Pricing and availability is not currently available.
radiello On-Field Thermometer, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
Pricing and availability is not currently available.
radiello BTEX/VOC Starter Kit, CS2 Desorption
Pricing and availability is not currently available.
radiello BTEX/VOC Starter Kit, Thermal Desorption
Pricing and availability is not currently available.
radiello On-Field Thermometer, Reader, pk of 1
Pricing and availability is not currently available.
radiello Diffusive Bodies, blue, configured for sampling light sensitive compounds, pk of 20
Pricing and availability is not currently available.
radiello 1,3-Butadiene Starter Kit, Thermal Desorption, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
Pricing and availability is not currently available.
Sigma-Aldrich
(R)-(−)-Mandelic acid, ChiPros®, produced by BASF, 99%
Pricing and availability is not currently available.
Sigma-Aldrich
Styrene, ReagentPlus®, contains 4-tert-butylcatechol as stabilizer, ≥99%
Pricing and availability is not currently available.
Sigma-Aldrich
Phenylglyoxylic acid, 97%
Pricing and availability is not currently available.
Sigma-Aldrich
(R)-(−)-Mandelic acid, ReagentPlus®, ≥99%
Pricing and availability is not currently available.
Supelco
Styrene, analytical standard
Pricing and availability is not currently available.
Sigma-Aldrich
Mandelic acid, 99%
Pricing and availability is not currently available.
Sigma-Aldrich
Phenylglyoxylic acid, purum, ≥98.0% (T)
Pricing and availability is not currently available.
Sigma-Aldrich
(R)-(−)-Mandelic acid, 98%
Pricing and availability is not currently available.
radiello Empty Storage Tubes, polypropylene (with stopper), volume 12 mL, pk of 100
Pricing and availability is not currently available.
radiello Diffusive Bodies, white, configured for general use, pk of 20
Pricing and availability is not currently available.
Supelco
radiello Methylene Blue Calibration Standard for H2S (Hydrogen Sulfide), pkg of 100 mL
Pricing and availability is not currently available.