Skip to Content
MilliporeSigma
  • Simultaneous determination of propofol and its glucuronide in whole blood by liquid chromatography-electrospray tandem mass spectrometry and the influence of sample storage conditions on the reliability of the test results.

Simultaneous determination of propofol and its glucuronide in whole blood by liquid chromatography-electrospray tandem mass spectrometry and the influence of sample storage conditions on the reliability of the test results.

Journal of pharmaceutical and biomedical analysis (2015-03-17)
Lambert K Sørensen, Jørgen B Hasselstrøm
ABSTRACT

Propofol (2,6-diisopropylphenol) is commonly used as an anaesthetic agent but is also abused for recreational purposes. Several cases of fatalities involving self-administered propofol have been reported. For rapid quantification of propofol and propofol β-d-glucuronide (propofol G) in clinical and forensic cases, an ultra-performance liquid chromatography-tandem mass spectrometry method using pneumatically assisted electrospray ionisation has been developed. The technique has been validated on both ante-mortem and post-mortem human whole blood. The proteins in the blood samples were removed by the addition of a mixture of methanol and acetonitrile, and the extract was cleaned up by solid phase extraction. The extract was concentrated in dimethyl sulphoxide. The system was calibrated using matrix-matched calibrants combined with isotope dilution. The lower limits of quantification were 0.01 and 0.02mg/L for propofol and 0.02 and 0.04mg/L for propofol G in ante-mortem and post-mortem whole blood, respectively. The relative intra-laboratory reproducibility standard deviation was less than 10% at concentrations of 0.2mg/L or higher. The mean true extraction recovery was 85% for propofol and 81% for propofol G. The trueness of the propofol determination expressed as the relative bias of the test results was within ±6% at concentration levels of 0.01-8.5mg/L. Propofol was less stable in blood stabilised with a citrate-EDTA-fluoride mixture than in blood stabilised with an oxalate-fluoride mixture. The stability was lower at -20°C than at 5°C and -80°C. Propofol G did not show instability under the storage conditions tested.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile, suitable for residue analysis, JIS 5000
Sigma-Aldrich
Acetonitrile, suitable for chromatography
Sigma-Aldrich
Dimethyl sulfoxide, suitable for HPLC
Sigma-Aldrich
Dimethyl sulfoxide, ≥99.5%
Supelco
5α-Androstan-17β-ol-3-one, VETRANAL®, analytical standard
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 300
Sigma-Aldrich
Dimethyl sulfoxide solution, 50 wt. % in H2O
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 1000
Sigma-Aldrich
Dimethyl sulfoxide, JIS special grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Dimethyl sulfoxide, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
Dimethyl sulfoxide, ≥99.0%, suitable for absorption spectrum analysis
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Millipore
Bifido Selective Supplement B, suitable for microbiology
Supelco
Acetonitrile, HPLC grade, ≥99.93%
Sigma-Aldrich
Dimethyl sulfoxide, ≥99.6%, ReagentPlus®
Sigma-Aldrich
2,6-Diisopropylphenol, 97%
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, ≥97.5%
Sigma-Aldrich
Dimethyl sulfoxide, meets EP testing specifications, meets USP testing specifications
Sigma-Aldrich
Dimethyl sulfoxide, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
Dimethyl sulfoxide, PCR Reagent
Sigma-Aldrich
Dimethyl sulfoxide, Molecular Biology
Sigma-Aldrich
Dimethyl sulfoxide, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Supelco
Dimethyl sulfoxide, analytical standard
Sigma-Aldrich
Dimethyl sulfoxide, anhydrous, ≥99.9%
Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Dimethyl sulfoxide, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma