Fluctuations in HPLC pump pressure can commonly be attributed to air bubbles in the mobile phase line. Ensuring that all fittings are secured properly, verifying flow rates, and priming the system to remove air bubbles are essential steps. If issues persist, cleaning or replacing check valves and pistons as per the manufacturer's guidelines is recommended. Preventive maintenance, such as filtering solvents and regular system checks, along with the use of a back pressure regulator, can also help stabilize pump pressure and prevent fluctuations.
Select a Size
| Size/SKU | Availability | Price |
|---|
About This Item
Product Name
Acetonitrile, anhydrous, Biosynthesis OmniSolv®, ≥99.9% (GC)
grade
anhydrous
vapor density
1.41 (vs air)
vapor pressure
72.8 mmHg ( 20 °C), 97 hPa ( 20 °C)
description
gradient analysis: <=0.003 at 210nm
product line
OmniSolv®
assay
≥99.9% (GC)
form
liquid
autoignition temp.
973 °F
expl. lim.
16 %
technique(s)
GC/GC: suitable
impurities
≤0.16 μeq/g Titrable base, ≤0.20 ppm Free amine (as dimethylamine), ≤0.8 μeq/g Titrable acid, ≤10 ppm Water (H2O)
evapn. residue
≤1 ppm
color
APHA: ≤10
refractive index
n20/D 1.344 (lit.)
bp
81-82 °C (lit.)
mp
−45 °C (lit.)
transition temp
flash point 2 °C
density
0.786 g/mL at 25 °C (lit.)
UV cutoff
≤189 nm
UV absorption
λ: 189 nm Amax: ≤1.00, λ: 195 nm Amax: ≤0.15, λ: 210 nm Amax: ≤0.03, λ: 230 nm Amax: ≤0.005, λ: 250 nm Amax: ≤0.005, λ: 270 nm Amax: ≤0.005
application(s)
pharmaceutical
format
neat
shipped in
ambient
storage temp.
room temp
SMILES string
CC#N
InChI
1S/C2H3N/c1-2-3/h1H3
InChI key
WEVYAHXRMPXWCK-UHFFFAOYSA-N
Application
Packaging
As a global leader in lab reagents, we are constantly looking for new ways to optimize the safety of our products. The newly developed 4L solvent bottle design features advanced sealing technology that eliminates leaks to make the handling of solvents safer and more convenient than ever before.
See all the new features here!
Preparation Note
Analysis Note
Legal Information
1 of 1
This Item | |||
|---|---|---|---|
| description anhydrous, Biosynthesis OmniSolv®, ≥99.9% (GC) | description anhydrous, Biotechnology, ≥99.9% (GC) | description suitable for DNA synthesis, ≥99.9% (GC) | description JIS special grade, ≥99.5% |
| assay ≥99.9% (GC) | assay ≥99.9% (GC) | assay ≥99.9% (GC) | assay ≥99.5% |
| application(s) pharmaceutical | application(s) pharmaceutical | application(s) - | application(s) - |
| grade anhydrous | grade anhydrous, biotech. grade | grade - | grade JIS special grade |
| Quality Level 300, 200 | Quality Level 200, 300 | Quality Level 100 | Quality Level - |
| technique(s) GC/GC: suitable | technique(s) GC/GC: suitable | technique(s) DNA synthesis: suitable, cDNA synthesis: suitable | technique(s) - |
| form liquid | form liquid | form liquid | form liquid |
Still not finding the right product?
Explore all of our products under Acetonitrile
Signal Word
Danger
Hazard Codes
Precautionary Statements
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class
3 - Flammable liquids
Flash Point (°F)
35.6 °F - closed cup
Flash Point (°C)
2.0 °C - closed cup
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
-
What factors cause fluctuations in HPLC pump pressure?
1 answer-
Helpful?
-