MilliporeSigma
All Photos(1)

A0561

Sigma-Aldrich

ACCUSPIN System-Histopaque®-1077

MDL number:
NACRES:
NA.75

sterility

aseptically filled

Quality Level

shelf life

Expiry date on the label.

packaging

package of 100 tubes

application(s)

hematology
histology

storage temp.

2-8°C

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
A7054A6929H8889
shelf life

Expiry date on the label.

shelf life

Expiry date on the label.

shelf life

Expiry date on the label.

shelf life

-

packaging

package of 100 tubes

packaging

-

packaging

-

packaging

-

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

Quality Level

400

Quality Level

400

Quality Level

400

Quality Level

400

luminometer, plasma separation, serum separation, molecular separation, separation by molecular weight, extraction and separation, cell separation, mixture separation, tissue separation, thermal cycler, lymphocytes seperation, whole blood seperation,

luminometer, plasma separation, serum separation, molecular separation, separation by molecular weight, extraction and separation, cell separation, mixture separation, tissue separation, thermal cycler, lymphocytes seperation, whole blood seperation,

luminometer, plasma separation, serum separation, molecular separation, separation by molecular weight, extraction and separation, cell separation, mixture separation, tissue separation, thermal cycler, lymphocytes seperation, whole blood seperation,

density gradient, gradient centrifugation, lymphocyte purification reagent

General description

ACCUSPIN System-Histopaque-1077 products are intended for use in the isolation of lymphocytes and other mononuclear cells. The separation medium, Histopaque-1077, is a sterile-filtered, endotoxin-tested solution of polysucrose and sodium diatrizoate, adjusted to a density of 1.077 g/mL. ACCUSPIN System-HISTOPAQUE-1077 employs centrifuge tubes specially designed with two chambers separated by a porous high-density polyethylene barrier ("frit").

γ-irradiated 50 mL polypropylene tubes fitted with a HDPE porous barrier and asepticallyfilled with 15 mL of Histopaque 1077. Each tube will separate 15-30 mL of anticoagulated blood.

Application

ACCUSPIN System-Histopaque-1077 is used for the separation of lymphocytes and other mononuclear cells from whole blood and bone marrow using density gradient separation media. Histopaque 1077 is suitable for human lymphocyte antigen (HLA) typing and as the initial isolation step prior to enumeration of T, B, and ‘null’ lymphocytes. It may also be employed in the preparation of pure lymphocyte suspensions for cell culture and cytotoxicity assays.

It is also suitable for the purification of human bone marrow aspirates to investigated the therapeutic value of BET inhibitors for acute myeloid leukemia.
ACCUSPIN System-HISTOPAQUE-1077 employs centrifuge tubes specially designed with two chambers separated by a porous high-density polyethylene barrier ("frit"). The lower chamber contains HISTOPAQUE-1077 which allows the addition of anticoagulated whole blood without risk of mixing with the separation medium. On centrifugation, the whole blood descends through the frit to contact with the HISTOPAQUE-1077 below the frit, giving a clear separation of the blood components. The erythrocytes aggregate and the granulocytes become slightly hypertonic, increasing their sedimentation rate, resulting in pelleting at the bottom of the ACCUSPIN tube. Lymphocytes and other mononuclear cells, i.e., monocytes, remain at the plasma-HISTOPAQUE-1077 interface.

Features and Benefits

ACCUSPIN System-Histopaque®-1077 offers numerous advantages, such as:

  • Optimal recovery of viable cells
  • Permits selective separation of blood cell types
  • Prevents cell distortion
  • Preserves cell viability
  • Minimal extraneous cell interference
  • Reproducible performance from batch to batch
  • Histopaque is sterile-filtered and endotoxin-tested
  • Stable at 2-8°C for at least 2 years when protected from light

Principle

The lower chamber contains HISTOPAQUE-1077 which allows the addition of anticoagulated whole blood without risk of mixing with the separation medium. On centrifugation, the whole blood descends through the frit to contact with the HISTOPAQUE-1077 below the frit, giving a clear separation of the blood components. The erythrocytes aggregate and the granulocytes become slightly hypertonic, increasing their sedimentation rate, resulting in pelleting at the bottom of the ACCUSPIN tube. Lymphocytes and other mononuclear cells, i.e., monocytes, remain at the plasma-HISTOPAQUE-1077 interface.

Legal Information

Accuspin is a trademark of Sigma-Aldrich Co. LLC
Histopaque is a registered trademark of Sigma-Aldrich Co. LLC

Pictograms

Health hazard

Signal Word

Danger

Hazard Statements

Hazard Classifications

Resp. Sens. 1 - Skin Sens. 1

Storage Class Code

12 - Non Combustible Liquids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 10

1 of 10

Ficoll®-Paque Premium Cytiva 17-5442-02, pack of 6 × 100 mL

GE17-5442-02

Ficoll®-Paque Premium

Greiner centrifuge tubes capacity 50 mL, conical bottom (with skirt), diam. × L 30 mm × 115 mm

T2193

Greiner centrifuge tubes

Sigma-Aldrich

Sigma-Aldrich

F5415

Ficoll® solution

Ficoll®-Paque PREMIUM 1.084 Cytiva 17-5446-02, pack of 6 × 100 mL

GE17-5446-02

Ficoll®-Paque PREMIUM 1.084

Sigma-Aldrich

Sigma-Aldrich

F2637

Ficoll® 400

Ficoll®-Paque PREMIUM 1.073 Cytiva 17-5446-52, pack of 6 × 100 mL

GE17-5446-52

Ficoll®-Paque PREMIUM 1.073

Ficoll® 400 Type 400-DL, lyophilized powder

Sigma-Aldrich

F9378

Ficoll® 400

Ficoll® Paque Plus Cytiva 17-1440-03, pack of 6 × 500 mL

GE17-1440-03

Ficoll® Paque Plus

Greiner centrifuge tubes centrifuge tube, 50 mL, 30 x 115 mm, conical (V) bottom, w/ graduations, I.D. field

T2318

Greiner centrifuge tubes

Janet C Lindow et al.
PLoS neglected tropical diseases, 6(7), e1742-e1742 (2012-07-21)
The four dengue virus serotypes (DENV-1-DENV-4) have a large impact on global health, causing 50-100 million cases of dengue fever annually. Herein, we describe the first kinetic T cell response to a low-dose DENV-1 vaccination study (10 PFU) in humans.
Nicolas Antoine-Moussiaux et al.
PloS one, 4(5), e5728-e5728 (2009-05-30)
In a recent study dealing with a mouse model of Trypanosoma evansi-associated disease, a remarkable synchrony between the parasitaemia peak and the white-blood-cell count nadir was noticed. The present study was designed to establish whether there is a direct causal
Tiffany A Greenwood et al.
PloS one, 7(1), e29630-e29630 (2012-01-19)
While it is clear that schizophrenia is highly heritable, the genetic basis of this heritability is complex. Human genetic, brain imaging, and model organism studies have met with only modest gains. A complementary research tactic is to evaluate the genetic

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service