コンテンツへスキップ
Merck

GC Analysis of Aldehydes (PFBOA Derivatives) in Beer on SLB®-5ms after SPME using a 65 μm PDMS/DVB Fiber

GC Analysis of Aldehydes (PFBOA Derivatives) in Beer on SLB®-5ms after SPME using a 65 μm PDMS/DVB Fiber suitable for GC, application for SPME

材料

used together

製品番号
詳細
価格

SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB)

65 μm PDMS/DVB, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, blue hub

関連製品

製品番号
詳細
価格

ベンズアルデヒド

analytical standard

フェニルアセトアルデヒド

≥95%, FCC, FG

SPMEファイバーホルダー

for use with Manual Sampling, pk of 1

SPMEファイバーホルダー

for use with CTC CombiPAL, Gerstel MPS2 Autosamplers, pk of 1

SLB®-5msキャピラリーGCカラム

L × I.D. 30 m × 0.25 mm, df 0.50 μm

イソブチルアルデヒド

analytical standard

2-メチルブチルアルデヒド

analytical standard

イソバレルアルデヒド

analytical standard

trans-2-ノネナール

analytical standard

cis-11-ヘキサデセナール

analytical standard

2-フルアルデヒド

certified reference material, pharmaceutical secondary standard

CONDITIONS

sample preparation

derivatization procedure: Add 100 μL of PFBOA solution (6 g/L) to 10 mL of deionized water in a 20 mL glass vial and seal. (Insert the PDMS/DVB SPME fiber in the headspace of the PFBOA solution for 10 min at 50 °C.)

sample/matrix

10 mL of degassed beer, 3.5 gm sodium chloride in 20 mL vial

SPME fiber

PDMS-DVB, 23 guage, 65 μm, Auto, Pk/3 (57345-U)

extraction

60 min, headspace, 50 °C, agitation (5 min on, 30 min off)

desorption process

0.10 min, 250 °C

column

SLB-5ms, 30 m x 0.25 mm I.D., 0.50 μm (28473-U)

oven

40 °C, 7 °C/min to 250 °C (14 min)

inj. temp.

250 °C

detector

MSD, SIM

MSD interface

275 °C

carrier gas

helium, 1.1 mL/min

injection

splitless

liner

0.75 mm I.D. SPME liner

sample

Beer

詳細

アナリシスノート

The formation of aldehydes is a major contributor to the deterioration in flavor or "staling" of beer upon storage. Research indicates that the source of these aldehydes is the type of malt used and quality of the wort produced during the brewing process. This application illustrates the use of SPME to extract aldehydes from beer, followed by on-fiber derivatization with 0-(2,3,4,5,6- pentafluorobenzyl)hydroxylamine hydrochloride (PFBOA). The aldehydes are then analyzed by GC/MS-SIM as their corresponding PFBOA derivatives. The aldehydes exist as geometric isomers, resulting in two derivatives for each. In the case of several of the analytes, these two derivatives were resolved chromatographically.

法的情報

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany