About This Item
LC/MS: suitable
43 hPa ( 20 °C)
44 mmHg ( 25 °C)
Skip To
Product Name
2-Propanol, hypergrade for LC-MS LiChrosolv®
agency
suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for EPA 8327
Quality Level
vapor density
2.1 (vs air)
vapor pressure
33 mmHg ( 20 °C)
43 hPa ( 20 °C)
44 mmHg ( 25 °C)
product line
LiChrosolv®
assay
≥99.9% (GC)
form
liquid
autoignition temp.
750 °F
expl. lim.
2.0-12.7 %, 93 °C
greener alternative product characteristics
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.
sustainability
Greener Alternative Product
technique(s)
HPLC: suitable
LC/MS: suitable
impurities
≤0.0002 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.05% Water
≤10 ppb Al (Aluminium)
≤10 ppb Ca (Calcium)
≤10 ppb Fe (Iron)
≤10 ppb Mg (Magnesium)
≤150 ppb Na (Sodium)
≤5 ppb Any further metal (ICP-MS)
≤5 ppb K (Potassium)
evapn. residue
≤2.0 mg/L
color
APHA: ≤10
transmittance
220 nm, ≥80% (Checking after purging with N2)
230 nm, ≥90% (Checking after purging with N2)
250 nm, ≥99% (Checking after purging with N2)
refractive index
n20/D 1.377 (lit.)
pH
7 (20 °C)
bp
82 °C (lit.)
mp
−89.5 °C (lit.)
transition temp
flash point 12 °C
density
0.785 g/mL at 25 °C (lit.)
SMILES string
CC(C)O
application(s)
PFAS testing
greener alternative category
storage temp.
2-30°C
InChI
1S/C3H8O/c1-3(2)4/h3-4H,1-2H3
InChI key
KFZMGEQAYNKOFK-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
1 of 4
This Item | 1.01040 | 1.13350 | 1.00998 |
|---|---|---|---|
| Quality Level 100 | Quality Level 100 | Quality Level 200 | Quality Level 100 |
| technique(s) LC/MS: suitable | technique(s) HPLC: suitable | technique(s) - | technique(s) gas chromatography (GC): suitable |
| assay ≥99.9% (GC) | assay ≥99.9% (GC) | assay ≥99.8% (GC) | assay ≥99.8% (GC) |
| form liquid | form liquid | form liquid | form liquid |
| impurities ≤0.0002 meq/g Acidity, ≤0.05% Water, ≤10 ppb Ca (Calcium), ≤10 ppb Mg (Magnesium), ≤5 ppb Any further metal (ICP-MS), ≤0.0002 meq/g Alkalinity, ≤10 ppb Fe (Iron), ≤5 ppb K (Potassium), ≤10 ppb Al (Aluminium), ≤150 ppb Na (Sodium) | impurities ≤0.0002 meq/g Acidity, ≤0.0002 meq/g Alkalinity, ≤0.05% Water | impurities ≤0.0002 meq/g Acidity, ≤0.0002 meq/g Alkalinity, ≤0.05% Water | impurities - |
| mp −89.5 °C (lit.) | mp −89.5 °C (lit.) | mp −89.5 °C (lit.) | mp −89.5 °C (lit.) |
Application
Sample Preparation for LC-MS: 2-Propanol is essential for sample preparation in LC-MS applications, effectively dissolving and extracting analytes such as proteins, lipids, and small molecules from complex biological and environmental matrices.
Features and Benefits
Preparation Note
Analysis Note
Identity (IR): conforms
Evaporation residue: ≤ 2.0 mg/l
Color: ≤ 10 Hazen
Water: ≤ 0.05 %
Acidity: ≤ 0.0002 meq/g
Alkalinity: ≤ 0.0002 meq/g
Gradient grade (at 235 nm): ≤ 1.0 mAU
Gradient grade (at 254 nm): ≤ 1.0 mAU
Fluorescence (as quinine at 254 nm): ≤ 1.0 ppb
Fluorescence (as quinine at 365 nm): ≤ 0.5 ppb
Transmission (Checking after purging with N₂ (at 220 nm)): ≥ 80 %
Transmission (Checking after purging with N₂ (at 230 nm)): ≥ 90 %
Transmission (Checking after purging with N₂ (from 250 nm)): ≥ 99 %
Al (Aluminium): ≤ 10 ppb
Ca (Calcium): ≤ 10 ppb
Fe (Iron): ≤ 10 ppb
K (Potassium): ≤ 5 ppb
Mg (Magnesium): ≤ 10 ppb
Na (Sodium): ≤ 150 ppb
Any further metal (ICP-MS): ≤ 5 ppb
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI positive): ≤ 10 ppb
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI negative): ≤ 20 ppb
Filtered by 0.2 µm filter.
Other Notes
Legal Information
related product
signalword
Danger
hcodes
Hazard Classifications
Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3
target_organs
Respiratory system
Storage Class
3 - Flammable liquids
wgk_germany
WGK 1
flash_point_f
53.6 °F - closed cup
flash_point_c
12.0 °C - closed cup
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
Polar graphitic carbon enables UHPLC separation of highly polar pesticides, herbicides, and Vitamin D metabolites, advancing liquid chromatography capabilities.
Determination of plasma protein binding using a SupelTM C18 pin device based BioSPME method for efficient sample preparation, along with a comparison to the equilibrium dialysis method.
Comparative analysis of Supel™ BioSPME 96-Pin device with a rapid equilibrium dialysis technique for accuracy of measured values, sample cleanliness, and workflow time in drug protein binding.
Learn about Supel™ BioSPME C18 high-throughput devices to determine plasma protein binding and decrease the sample preparation time to less than an hour.
Related Content
Las PFAS o «productos químicos eternos», persisten en el medio ambiente y pueden suponer un riesgo para la salud humana. Descubra nuestras herramientas de control medioambiental para cuantificación de las PFAS, para apoyar a los investigadores, reguladores y laboratorios en sus análisis de las PFAS.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service